CDZFD - 209966, DESICCANT REPLACEMENT KIT (MURRAY, NAPA OR ATLAS)

  • MSDS: CDZFD
  • Manufacturer: UNION CARBIDE CORP LINDE DIV
  • Product Name: 209966, DESICCANT REPLACEMENT KIT (MURRAY, NAPA OR ATLAS)
  • National Stock Number: 6850-00D006952
Product Identification

Product ID:209966, DESICCANT REPLACEMENT KIT (MURRAY, NAPA OR ATLAS)
MSDS Date:09/27/1989
FSC:6850
NIIN:00D006952
MSDS Number: CDZFD

Responsible Party
UNION CARBIDE CORP LINDE DIV
39 OLD RIDGEBURY RD
DANBURY, CT 06817-0001
US

Emergency Phone: 203-744-3487

Info Phone: 203-744-3487

Preparer: ARTHUR G. HOBBS JR.

Cage: 36346

Contractor
UNION CARBIDE CORP LINDE DIV
DANBURY, CT 06817-0001 US

Telephone: 800-822-4357; 304-744-3487

Cage: 36346

Ingredients

SODIUM OXIDE

CAS: 1313-59-3

Fraction By Weight: <30%


SILICA, CRYSTALLINE - QUARTZ

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: <50%

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.1 MG/M3 RDUST;9495


ALPHA-ALUMINA (ALUMINUM OXIDE) (SARA 313)

CAS: 1344-28-1

RTECS: BD1200000

Fraction By Weight: <40%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9495

Hazards

LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONTACT W/MOISTURE (WATER), CAN CAUSE
RISE IN TEMPERATURE WHICH MAY RESULT IN BURNS.
Explanation of Carcinogenicity:NONE LISTED.
Effects of Overexposure:EYE:MAY CAUSE IRRITATION. SKIN:MAY CAUSE
IRRITATION & REDDENING. INHALATION:MAY CAUSE IRRITATION OF NOSE &
THROAT, ACCOMPANIED BY COUGH & CHEST DISCOMFORT. INGESTION:NONE
KNOWN. CHRONIC-NO KNOWN EFF ECTS.
Medical Cond Aggravated by Exposure:MFR GAVE NO INFORMATION OF MSDS.

First Aid

First Aid:IF IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL ATTENTION.
EYE:FLUSH W/WATER FOR 15 MIN. SKIN:WASH W/SOAP & WATER.
INHALED:REMOVE FROM EXPOSURE. AID OR RESTORE BREATHING AS NEEDED.
INGESTED:DRINK LAR GE AMOUNTS OF WATER. NOTE TO PHYSICIAN:PRODUCT
IS A DESSICANT & GENERATES HEAT AS IT ABSORBES WATER. USED PRODUCT
CAN CONTAIN MATERIAL OF A HAZARDOUS NATURE. IDENTIFY THAT MATERIAL
& TREAT APPROPRIATE

Fire Fighting

Flash Point:DOES NOT BURN
Autoignition Temp:Autoignition Temp Text:N/A.
Lower Limits:N/A.
Upper Limits:N/A.
Extinguishing Media:UNUSED MATERIAL WILL NOT BURN. USE EXTINGUISHING
MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:DEPENDS ON USE OF MATERIAL. USED MATERIAL MAY
CONTAIN HAZARDOUS PRODUCTS. USER MUST IDENTIFY HAZARDS OF RETAINED
MATERIAL & INFORM FIREFIGHTERS OF THOSE HAZARDS
Unusual Fire/Explosion Hazard:UNUSED MOLECULAR SIEVES AFE NOT
FLAMMABLE. THEY MAY GET HOT IF EXPOSED TO WATER. THEY CAN, WHEN
FIRST WETTED EXCEED BOILING POINT OF WATER. USE FLOODING AMOUNT.

Accidental Release

Spill Release Procedures:SWEEP SPILL AREA. COLLECT & PLACE IN A WASTE
DISPOSAL CONTAINER. AVOID RAISING DUST.
Neutralizing Agent:MFR GAVE NO INFORMATION OF MSDS.

Handling

Handling and Storage Precautions:IF IN AN AQUEOUS SLURRY, PH IS 8-11.
Other Precautions:PRODUCT IS SOLD IN FRLT BAGS CONTAININT 3 CU.IN. OF
DESSICANT PACKED IN A VACUUM SEALED ALUMINUM OUTER BAG. USED TO
ABSORB MOISTURE IN REFRIGERANT. PRODUCT IN DUST FORM IS NOT LIKELY
IN THIS APPLICATI ON.

Exposure Controls

Respiratory Protection:WHEN THERE IS EXCESSIVE DUSTINESS, WEAR A
NIOSH/MSHA APPROVED RESPIRATOR PURSUANT TO OSHA 29CFR1910,134.
Ventilation:LOCAL VENTILATION AS APPROPRIATE TO MINIMIZE DUST.
MECHANICAL VENTILATION IS NOT APPLICABLE.
Protective Gloves:PROTECTIVE GLOVES AS RECOMMENDED.
Eye Protection:WEAR SAFETY GLASSES / OSHA 29CFR1910.133
Other Protective Equipment:EYE WASH FORUNTAIN AS A PRECAUTION.
Work Hygienic Practices:MFR GAVE NO INFORMATION OF MSDS.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:N/A.
Vapor Pres:N/A.
Vapor Density:N/A.
Spec Gravity:1.1
pH:N/A.
Evaporation Rate & Reference:N/A.
Solubility in Water:N/A.
Appearance and Odor:SOLID, BEAT, PELLET, MESH, CAKE OR POWDER, COLOR
VARIES, ODORLESS
Percent Volatiles by Volume:N/A.

Stability

Stability Indicator/Materials to Avoid:YES
SUDDEN CONTACT W/CHEMICALS HAVING HIGH HEATS OF ABSORPTION SUCH AS
OLEFINS, HCL, OTHERS
Stability Condition to Avoid:MFR GAVE NO INFORMATION OF MSDS.
Hazardous Decomposition Products:HAZARDOUS MATERIALS THAT CONTACT
MOLECULAR SIEVE MAY BE RETAINED & THEIR DECOMPOSITION OR RELEASE
MAY OCCUR.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISCARD ANY PRODUCT RESIDUE, DISPOSABLE
CONTAINER OR LINER IN AN ENVIRONMENTALLY ACCEPTABLE MANNER IN FULL
COMPLIANCE W/FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.